Opens
Verifying
Now closing!
Closed
()

517 - AEC Systems Two-stage wet washing system

Lichtenvoorde | NL
0 Bid Bids Highest bidder Outbid

My last bid: €0.00 (Auto bid)

Share:

Product information

Brand AEC Systems
Amount 1

Air volume silos and process room: 8,500 m3/h
Ammonia concentration: 50 ppm
Temperature: 2-40 C
It can neutralise H2S and NH3.
A two-stage system can neutralise both substances effectively. In the first stage, water with H2SO4 (sulphuric acid) is added to the washing water to neutralise the ammonia and convert it into almost odourless ammonium sulphate. This stage is necessary because ammonia prevents other substances in the process air from being absorbed.
After the ammonia has been removed, the process air enters the second stage, where caustic soda (NaOH) is added. At a pH above 7, the washing water is able to absorb the H2S. With a sufficient surface area (= residence time) in the scrubber, it is possible to wash out 99.9% of the strong-smelling substance.

Please note! This lot is located in a water treatment plant. Professional dismantling required. Work can only commence once the seller has approved the safety plan.

Important information

Lot collections will take place on the specified pickup days but according to a delivery schedule which will be sent after the auction has closed. A professional service partner for pickup assistance (dismantling, loading, transport) is available; contact details will be shared with all buyers immidiately after the sale closure.

Air volume silos and process room: 8,500 m3/h
Ammonia concentration: 50 ppm
Temperature: 2-40 C
It can neutralise H2S and NH3.
A two-stage system can neutralise both substances effectively. In the first stage, water with H2SO4 (sulphuric acid) is added to the washing water to neutralise the ammonia and convert it into almost odourless ammonium sulphate. This stage is necessary because ammonia prevents other substances in the process air from being absorbed.
After the ammonia has been removed, the process air enters the second stage, where caustic soda (NaOH) is added. At a pH above 7, the washing water is able to absorb the H2S. With a sufficient surface area (= residence time) in the scrubber, it is possible to wash out 99.9% of the strong-smelling substance.

Please note! This lot is located in a water treatment plant. Professional dismantling required. Work can only commence once the seller has approved the safety plan.

Viewing days

: -

Aaltenseweg 4
7131 ND Lichtenvoorde (Netherlands)

: -

Aaltenseweg 4
7131 ND Lichtenvoorde (Netherlands)

: -

Aaltenseweg 4
7131 ND Lichtenvoorde (Netherlands)

Pick-up days

Pickup according to schedule (information to follow after auction) : -

Aaltenseweg 4
7131 ND Lichtenvoorde (Netherlands)

Pickup according to schedule -
: -

Aaltenseweg 4
7131 ND Lichtenvoorde (Netherlands)

Relevant lots

  • Overview picture of 2002 MTS 2001 Industrial Sweeper
    0 Bid Bids Highest bidder Outbid

    500 - 2002 MTS 2001 Industrial Sweeper

    Depot Deinze | Belgium

    Forklift accessories

    €500.00

  • Overview picture of AJK Slurry Spreader
    0 Bid Bids Highest bidder Outbid

    4013 - AJK Slurry Spreader

    Herent | Belgium

    Slurry Tanks

    €400.00

  • Overview picture of 2006 PCM DD1 SSC Mobile Wastewater Pump with Frequency Control
    0 Bid Bids Highest bidder Outbid

    557 - 2006 PCM DD1 SSC Mobile Wastewater Pump with Frequency Control

    Diksmuide | Belgium

    Pomp units

    €150.00