Ouvre
Vérification
Fermeture en cours !
Fermé
()

517 - AEC Systems Two-stage wet washing system

Lichtenvoorde | NL
0 Enchère Enchères Enchérisseur le plus élevé Surenchéri

Ma dernière enchère: 0,00 € (Enchère automatique)

Partager

Informations sur le produit

Marque AEC Systems
Quantité 1

Air volume silos and process room: 8,500 m3/h
Ammonia concentration: 50 ppm
Temperature: 2-40 C
It can neutralise H2S and NH3.
A two-stage system can neutralise both substances effectively. In the first stage, water with H2SO4 (sulphuric acid) is added to the washing water to neutralise the ammonia and convert it into almost odourless ammonium sulphate. This stage is necessary because ammonia prevents other substances in the process air from being absorbed.
After the ammonia has been removed, the process air enters the second stage, where caustic soda (NaOH) is added. At a pH above 7, the washing water is able to absorb the H2S. With a sufficient surface area (= residence time) in the scrubber, it is possible to wash out 99.9% of the strong-smelling substance.

Please note! This lot is located in a water treatment plant. Professional dismantling required. Work can only commence once the seller has approved the safety plan.

Informations importantes

Lot collections will take place on the specified pickup days but according to a delivery schedule which will be sent after the auction has closed. A professional service partner for pickup assistance (dismantling, loading, transport) is available; contact details will be shared with all buyers immidiately after the sale closure.

Air volume silos and process room: 8,500 m3/h
Ammonia concentration: 50 ppm
Temperature: 2-40 C
It can neutralise H2S and NH3.
A two-stage system can neutralise both substances effectively. In the first stage, water with H2SO4 (sulphuric acid) is added to the washing water to neutralise the ammonia and convert it into almost odourless ammonium sulphate. This stage is necessary because ammonia prevents other substances in the process air from being absorbed.
After the ammonia has been removed, the process air enters the second stage, where caustic soda (NaOH) is added. At a pH above 7, the washing water is able to absorb the H2S. With a sufficient surface area (= residence time) in the scrubber, it is possible to wash out 99.9% of the strong-smelling substance.

Please note! This lot is located in a water treatment plant. Professional dismantling required. Work can only commence once the seller has approved the safety plan.

Jours de visite

: -

Aaltenseweg 4
7131 ND Lichtenvoorde (Pays-Bas)

: -

Aaltenseweg 4
7131 ND Lichtenvoorde (Pays-Bas)

: -

Aaltenseweg 4
7131 ND Lichtenvoorde (Pays-Bas)

Jours de retrait

A collecter sur rendez-vous le (informations à suivre après l'enchère) : -

Aaltenseweg 4
7131 ND Lichtenvoorde (Pays-Bas)

A collecter sur rendez-vous le -
: -

Aaltenseweg 4
7131 ND Lichtenvoorde (Pays-Bas)

Lots concernés

  • Photo d'aperçu de 2002 MTS 2001 : balayeuse industrielle à brosses
    0 Enchère Enchères Enchérisseur le plus élevé Surenchéri

    500 - 2002 MTS 2001 : balayeuse industrielle à brosses

    Depot Deinze | Belgique

    accessoires de chariot élévateur

    500,00 €

  • Photo d'aperçu de Épandeur d'engrais mélangé AJK
    0 Enchère Enchères Enchérisseur le plus élevé Surenchéri

    4013 - Épandeur d'engrais mélangé AJK

    Herent | Belgique

    Réservoirs à boue

    400,00 €

  • Photo d'aperçu de Pompe mobile pour eaux usées PCM DD1 SSC 2006 à régulation de fréquence
    0 Enchère Enchères Enchérisseur le plus élevé Surenchéri

    557 - Pompe mobile pour eaux usées PCM DD1 SSC 2006 à régulation de fréquence

    Diksmuide | Belgique

    unités de pompe

    150,00 €